Axpert King II Off-Grid Inverter Specification 

 

MODEL  Axpert KING II-5000-48
Rated Power  5000VA/5000W
Parallel Capability  Up to 9 units
GRID INPUT
Voltage  230 VAC
Voltage Range  110-280 VAC 
Frequency Range  50 Hz/60 Hz (Auto sensing) ± 4Hz
Power Factor  ≧ 0.98 @ Nominal Voltage (100% Load)
THDi  ≦ 10%
LOAD OUTPUT
AC Voltage Regulation (Line&Batt. Mode)  230VAC ± 5%
Frequency Range (Synchronized Range)  46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode)  50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Harmonic Distortion  ≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load)
Transfer  

Time

AC Mode to Batt. Mode  0 ms 
Inverter to Bypass  4 ms (Typical)
Waveform  Pure sine wave
EFFICIENCY
Line Mode  94%
ECO Mode  98%
Battery Mode  92%
BATTERY 
Battery Voltage  40~62 VDC
Floating Charge Voltage  54 VDC
Overcharge Protection  62 VDC
SOLAR INPUT
Solar Charger type  MPPT
Maximum PV Array Power  6000 W
MPPT Range @ Operating Voltage  120 ~ 450 VDC
Maximum PV Array Open Circuit Voltage  500 VDC
Maxmum Solar Charge Current  100A
Maximum AC Charge Current  100A
PHYSICAL
Dimension, D x W x H (mm)  138.4 x 298 x 467.6
Net Weight (kgs)  12
Communication Interface  RS232, USB, DRY CONTACT, WI-FI, RS485, CAN
ENVIRONMENT
Humidity  5% to 95% Relative Humidity(Non-condensing)
Operating Temperature  -10°C to 50°C
Storage Temperature  -15°C to 60°C
Additional information
1.

Detachable LCD control module with multiple communications.

2.

5000W wide MPPT (120~450vdc) charge controller.

3.

Built-in Bluetooth for mobile monitoring(Android App is available).

4.

Support USB on-the-go function.

5.

Reversed communication port for BMS (RS485, CAN-BUS or R232).

6.

A replaceable fan designed for ease of maintenance.

7.

Supply load from Grid or PV, even battery is not available.

8.

Configure AC/PV output usage timer and prioritization.

9.

Selectable high power charging current.

10.

Auto restart while AC is recovering.

11.

Cold start function.

Reviews (0)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.