Item | General Parameter | Remark |
Combination Method | 15S | |
Rated Capcity | Typical-100Ah, Minimum-100Ah | Standard Discharge After Standard Charge(Package) |
Factory Voltage | 49.5-50.5V | Mean Operation Voltage |
Voltage at end of Discharge | 40-42.5V | Discharge Cut-Off Voltage |
Charging Voltage | 53.2-54V | |
Internal Impedance | ≤50mΩ | Internal resistance measured at AC 1KHZ after 50% charge The measure must uses the new batteries that within one week after shipment and cycles less than 5 times |
Standard charge | Constant Current 20A Constant Voltage see No.5 0.01CA cut-off |
Charge time : Approx 6h |
Standard discharge | Constant current:20A end voltage see NO.4 |
|
Maximum Continuous Charge Current |
100A | |
Maximum Continuous Discharge Current |
120A | |
Operation Temperature Range |
Charge: 0~45°C, Discharge: -20~55°C | 60±25%R.H. Bare Cell |
Storage Temperature Range |
Less than 12 months : -10~35℃, less than 3 months: -10~45℃, Less than 7 day : -20~65℃ |
60±25%R.H. at the shipment state |
Cycle life | ≥4500cycle | at 80% DOD |
Dimensions | 480*450*222 mm | Include case |
Weight | 48kg | Include case |
Volumetric specific energy |
100 WH/L | Include case |
Gravimetric specific energy |
99WH/KG | Include case |